Find gas leaks while meeting governmental and environmental emission goals with the FLIR G620a: a long-lived, cooled OGI camera solution for continuous monitoring at upstream and midstream gas production and processing facilities. The G620a is spectrally filtered to see methane (CH₄), hydrocarbons, and Volatile Organic Compounds (VOCs) with a performance OGI detector that meets sensitivity requirements set forth in U.S. EPA OOOOa and Appendix K. Small and lightweight, the G620a installs quickly and relies on a simplified web interface. Never miss a moment of monitoring thanks to the robust linear cooler which supports 27,000 hours of non-stop operation. The FLIR G620a can help oil and gas companies maintain valuable capital equipment, avoid product loss, meet emissions reduction metrics, and ensure safer work practices.
- Products
- Industrial
- Fixed Thermal Cameras
- FLIR G620a
Added to cart
-
Unmatched image clarity
The high-resolution, high sensitivity cooled image sensor plus the advantage of FLIR's proprietary High Sensitivity Mode (HSM) allows users to visualize even the smallest gas leaks.
-
Consistent leak monitoring, without interruption
FLIR G620a cameras offer more than 27,000 hours of runtime before any service is required (mean time to failure).
-
Meets emission regulations and reduction goals
Satisfy U.S. EPA methane and VOC detection sensitivity requirements and achieve global ESG pledges for methane and hydrocarbon reduction.
Set Up and Connect—Quickly and Easily
Connect and run cameras easily through included web interface, available software development kits (SDKs), and industry-standard protocol GigE vision.
Contact Sales
Want more information on this product?
Call +1 (866) 477-3687 to speak with a knowledgeable specialist.
Specifications
- IR Resolution
- 640 × 512
- Thermal Sensitivity/NETD
- <15 mK at 25°C
- Spectral Range
- 3.2–3.4 μm
Imaging & Optical
- Automatic Image Adjustment
- Linear, PE
- Color Palettes
- Selectable 8-bit
- Detector Pitch
- 15 µm
- Detector Type
- High Operating Temperature (HOT) MWIR T2SLS
- Digital image enhancement
- High sensitivity mode (HSM)
- Field of view (FOV)
- 14.4° × 11.5°
- f-number
- f/1.59
- Focal Length
- 38 mm
- Focus
- Motorized
- Gas Sensitivity [NECL]
- NECL: 1 m ΔT 10°C Methane: 16 ppm × m Hydrocarbons (niabara gas mix): 6.4 ppm × m
- Image Frequency
- 30 Hz
- Image Modes
- IR image, high sensitivity mode (HSM)
- IR Resolution
- 640 × 512
- Minimum Focus Distance
- 0.5 m (1.64 ft)
- Non-Radiometric IR Video
- Streaming H.264 or MJPEG over RTSP
- Non-radiometric IR video recording
- None
- Overlay
- RTSP only
- Radiometric IR video recording
- None
- Radiometric IR video streaming
- GigE Vision
- Sensor Cooling
- FLIR FL100 Linear cooler
- Spectral Range
- 3.2–3.4 μm
- Thermal Sensitivity/NETD
- <15 mK at 25°C
- Zoom
- Digital zoom, 1x, 2x, 4x, 8x
Measurement & Analysis
- Accuracy
- ≤100°C ±2°C, >100°C ±2% of reading
- Ambient Drift Compensation [with factory cal]
- Yes
- DC Voltage
- Range: 18 V-56 V
- Object Temperature Range
- -10°C to 120°C (14°F to 248°F)
Communication & Data Storage
- Command and Control
- GEV: Genicam; RTSP: Web Interface, REST API
- Communication Interfaces
- Ethernet
- Digital I/O connector type
- M12 12-pin A-coded, Male (shared with external power)
- Digital Inputs
- 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
- Digital Outputs
- 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
- Storage Media
- None
- Synchronization Modes
- Sync In
General
- Box Contents
- Camera w/lens; M12 to RJ45F Cable (0.3 m), quick start guide, certificate of calibration
- Size [L × W × H]
- 229 × 76 × 95 mm (9.0 × 3.0 × 3.8 in)
- Size [L x W x H ] w/o Lens
- 200 × 76 × 92 mm (7.9 × 3.0 × 3.6 in)
- Weight
- 1.48 kg (3.22 lbs)
- Weight [without lens]
- 1.32 kg (2.9 lbs)
Power
- Power Consumption
- 25 W (cool down)
- Power Source
- Primary power source: PoE+ type 2 (30 W min)
Optional DC connection: M12 12-pin A-coded, male (shared with Digital I/O)
Environmental & Certifications
- Directives
- EMC: 2014/30/EU, WEEE: 2012/19/EU
- EMC
- EN55032:2015/A11:2020
EN55035:2017/A11:2020
FCC Part 15, Subpart B ClassA
KC C 9832 and KS C 9835
- Encapsulation
- IP50
- Mounting
- With mounting plate - 2 × 1/4"-20 tapped holes, 1 × 3/8"-16; tapped hole, 4 × #10-24 tapped holes Without mounting plate - 6 × #6-32
- Operating Temperature Range
- -20°C to 50°C (-4°F to 122°F)
- Shock
- 25 g, 6 ms; Half sine; ± 500 shocks; X,Y&Z (IAW MIL-STD-810H)
- Vibration
- 10-58 Hz, 0.15 mm; 58-500 Hz, 2 g; 5 cycles, 1 oct/min; X,Y&Z (IAW MIL-STD-810H)
Related Documents
Export Restrictions
Export Restrictions
The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.
Want more information on this product?
Call +1 (866) 477-3687 to speak with a knowledgeable specialist.